H1910-24-ML650
Hepatitis B Surface Antigen (HBsAg) (MaxLight 650)

Size
£778.00
- SKU:
- H1910-24-ML650
- Application:
- FLISA
- Purity:
- Purified by DEAE chromatography.
- Storage Conditions:
- 4°C Do Not Freeze
- Supplier:
- United States Biological
- Host:
- Mouse
- Immunogen:
- Highly purified Hepatitis B Surface Antigen.
- Clone:
- 8.F.132
- Format:
- Supplied as a liquid in PBS, pH 7.2. No preservative added. Labeled with MaxLight™650.
- Extra Details:
- MaxLight™ 650 is a new Far-IR stable dye conjugate comparable to Alexa Fluor™647, DyLight™649, Cy5™ and offers better labeling efficiency, brighter imaging and increased immunodetection. Absorbance (655nm); Emission (676nm); Extinction Coefficient 250,000. Hepatitis B is an infection of the liver caused by the hepatitis B virus. Approximately 5-10% of adults and 90% of babies who are infected with HBV will go on to carry the virus for the rest of their lives. These people will pass the virus onto others. HBV is excreted in body fluids such as semen, saliva, blood and urine in persons with acute or chronic infection. The route of transmission can include homosexual or heterosexual activity, blood-borne exposure (needles, transfusion), mother-infant, close personal contact and even by consuming contaminated food or water. Thus, Hepatitis B has become a major public health concern. When HBV invades the body it causes liver damage through induction of auto-immunity. Liver cell injury results from cytotoxic T cell activity rather than viral cytotoxic activity. The principal screening test for detecting current (acute or chronic) HBV infection is the identification of HBsAg, an envelope lipoprotein. This is the first immunological marker to appear in a patient’s serum and exist in high quantities in the blood. Patients who are HBsAg positive develop chronic persistent hepatitis (CPH) and chronic active hepatitis (CAH). Patients with CPH usually remain in good health. Those with CAH have progressive liver damage with the outcome being portal fibrosis, cirrhosis, or hepatocellular carcinoma. Screening for HBsAg is recommended for all donors, pregnant women and those individuals who at high risk. Presence of this marker is conclusive proof of HBV infection. This immunoassay measures HBsAg through antigen-antibody interactions. Applications: Suitable for use in FLISA. Other applications not tested. Recommended Dilutions: Optimal dilutions to be determined by the researcher. Storage and Stability: Store product at 4°C in the dark. DO NOT FREEZE! Stable at 4°C for 12 months after receipt as an undiluted liquid. Dilute required amount only prior to immediate use. Further dilutions can be made in assay buffer. Caution: MaxLight™650 conjugates are sensitive to light. For maximum recovery of product, centrifuge the original vial prior to removing the cap. Note: Applications are based on unconjugated antibody.
- Shipping Conditions:
- Blue Ice
